FAG series sewage pump design is unique, ensure a high stability during operation, to prevent the occurrence of accidents in the poor working environment. High performance and excellent cost-effectiveness.
Wilo - FAG
- Overheating protection: ≤4kW power of the pump with double metal temperature sensor Power ≥5.5kw pumps with thermistor PTC
- Leakage protection: For pumps power higher than or equal to 5.5kW, there are equipped with leakage sensors in the motor housing and oil chamber, to detect if any leakage in the motor. The sensor in the oil chamber could detect if any oil leakage into the oil chamber to further protect the motor damaged from more water leakage. The alarm will shut off the motor to avoid the damage of motor.
- There are protection function like lack-phase protection, overload protection, low-voltage protection, and short circuit protection available through the control panel.